Mohammad Abadi F, Mirfazeli A, Zaeri H, Nejabat M, taherizadeh M, Ariaie M, et al . Analysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA. mljgoums 2016; 10 (2) :52-57
URL: http://mlj.goums.ac.ir/article-1-851-en.html
1- Biochemistry & Metabolic Disorders Research Center, Golestan University of Medical Sciences, Gorgan, Iran
2- Cognitional Malformations Research Center, Golestan University of Medical Sciences, Gorgan, Iran
3- School of pharmacy, Mashhad university of Midical Science, Mashhad, Iran
4- Golestan University of Medical Sciences, Gorgan, Iran
5- Laboratory Sciences Research Center, Golestan University of Medical Science, Gorgan, Iran , joshaghani@goums.ac.ir
Abstract:   (10884 Views)

ABSTRACT

       Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA) in combination with 3- mercaptopropionic acid (3-MPA).

       Methods: Overall, 107 neonates and babies suspected of having metabolic disorder were enrolled in this study. The level of amino acids in plasma samples was analyzed within 65 minutes by HPLC with pre-column derivatization by OPA/3-MPA. This was a gradient RP-HPLC method that was performed using two solvents with a ratio of methanol and sodium acetate. L-norvaline internal standard was used as the reference peak for amino acids. Standard mixture of amino acids was used to determine the concentrations of amino acids.

        Results: According to the values of coefficient of variation obtained for each amino acid, the results indicated a good chromatographic separation of amino acids by this method. The use of OPA/3-MPA derivative reagent increased the efficiency and resolution of amino acids chromatographic separation.

      Conclusion: Due to simple preparation and accurate assessment, determination of plasma amino acids using OPA/3-MPA derivatives and RP-HPLC is a suitable method in many clinical samples.

Full-Text [PDF 565 kb]   (4291 Downloads)    
Research Article: Original Paper |
Received: 2016/07/25 | Accepted: 2016/07/25 | Published: 2016/07/25 | ePublished: 2016/07/25

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2007 All Rights Reserved | Medical Laboratory Journal

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.